| EXHAUST GAS COMPONENT MEASURMENT | ||||
| Image | Product | Model | Description | |
|
Ultra fast response gas analyzers NO/NOX | Model CLD 500* |
Adoption of industry-standard Chemiluminescence's Detection (CLD) Ultra fast response (2ms T90-10). 2-Channel sampling. Combustion analysis at every driving cycle. Exhaust sampling (at transient state) Catalyst sampling (NOx trap) In-cylinder sampling (NOx produced) *These instruments are made by Cambustion Ltd. U.K. and can be supplied in Japan only. |
|
|
Ultra fast response FID analyzers | Model HFR 500* |
Adoption of industry-standard Flame Ionization Detection (FID) Ultra fast response (0.9ms T90-10). 2-Channel sampling. Measurement of un-burnt gas mixture concentration to un-burnt HC concentration in combustion gas. Combustion analysis at every driving cycle ( - HC) In-cylinder sampling (combustion analysis) Exhaust gas sampling (at transient state) Catalyst sampling *These instruments are made by Cambustion Ltd. U.K. and can be supplied in Japan only. |
|
|
Ultra fast response gas analyzers | Model NDIR 500* |
Adoption of industry-standard NDIR analyzers. Fast response (8ms T90-10). 2-Channel sampling. Combustion analysis at every driving cycle ( CO2) Exhaust gas sampling (at transient state) Intake sampling (back flow of combustion gas) In-cylinder sampling (Measurement of internal EGR) *These instruments are made by Cambustion Ltd. U.K. and can be supplied in Japan only. |
|
|
"Cambustion" Sampling Valve | Model CSV 500* |
Min. valve duration: 1ms Lots of accessories available (for the cylinder) Sampling of particular crank window at any crank angle. In-cylinder measurement of CO2, NOx, HC & by a combination of "Cambustion" fast response gas analyzers. Compatibility with high speed running engines: N > 10,000 rpm. Effects due to dead gas excluded by adoption of the double -valve. *These instruments are made by Cambustion Ltd. U.K. and can be supplied in Japan only. |
|
|
Spark plug Resistance Monitors | Model SPR 100* |
Measurement of insulation resistance during engine running. 8 channels with visual displays. A tool for investigation of the spark plug fouling. Research of effects of engine oil additives or fuel injection system on the spark plug fouling. *These instruments are made by Cambustion Ltd. U.K. and can be supplied in Japan only. |
|
|
Automotive Emissions Analyzers | Model IRG-101 |
Simultaneous measurement of HC, CO, CO2 by a single light source and a single cell. Digitalization of analog light a.c. signal by the "Sokken" unique detection method. No span shift due to variation in light volume from light source. No drift due to constant temp. Control of the O2 sensor. Automatic calibration function provided as the standard. |
|
| DIESEL SMOKE DENSITY MEASUR | ||||
| Image | Product | Model | Description | |
|
Real time measurement of soot mass concentration
|
Model LEX-04B |
Real time measurement of soot mass concentration in diesel exhaust gases Fast response: 0.1s Raw gas direct sample Wide dynamic range: 0.15 `1000mg/m3 No effects against exhaust pressure and flow variation Most suitable for evaluation of engine exhaust performance and of DPF in transient running state in diesel exhaust gases Calculation of concentration from laser beam opacity in sample exhaust gas (Opacity light beam attenuation method) |
|
|
In-line opacity smoke meters | Model ILS-01C |
In-line measurement of diesel exhaust gases. Opacity indicated accuracy: }1%FS Temp. drift: }1%FS(operating temp.) Response time: 0.02sec (90% response) Power supply: 100VAC and 12VDC 2-Ch. Analog output: 0-100%/ 0-1V and 0-100%/0-10V |
|
|
Portable vehicular opacity smoke meters | Model SM-501 |
Very small and light weighted detector unit which reduces a burden on the exhaust pipe. Improvement in earthquake-proof structure based on Sokken"unique optical design. Adoption of synchronous detection method which is not easily susceptible to external effects. Fast response processing for transient measurements. Power saving design on battery operation. Low drift over wide range of temp. environment due through very precise temp. compensation. |
|
|
Upright automatic diesel smoke meters | Model GSM-3 series |
Compliance with JIS regulations. Automatic procedures of smoke measurement. Remote control operation Filter paper run-out indication Easy transportation on large castors |
|
|
Automatic diesel smoke meters for low concentration applications | Model GSM-3DL |
Improved sister unit to Model GSM-3. Better accuracy in low concentrations through improved photo-cell Assembly Digital indication for readability. Meter scale calibration: Fully scaling by calibration filter paper |
|
|
Variable flow type automatic smoke meters for low concentration applications | Model GSM-10 |
Better accuracy in lower concentration region through adoption of temp. compensated photo probe. Wider low concentration region by variable flow sampling (Max. 10L) Compliance with measurements by conventional JIS regulations. Filter paper run-out indication. Main purging (at sampling completed) and sub-purging (any time)provided. |
|
| A/F Ratio measurement | ||||
| Image | Product | Model | Description | |
|
High precision A/F ratio meters | Model MCS-2 |
Sampling for manifold. High response: 0.3 sec (T90) Totally balanced specifications and wider range of applications. GPIB interface provided as standard. Option: Buffer memory (60 sec) provided. Option: Fast response and compensated calculation circuit provided. |
|
|
Portable A/F ratio meters | Model PLR-5 |
Compact design and simple operation. - 7 Cold start Measurement over wider range of AFR (10- 60 AFR with "UEGO"lean sensor) Small difference in indication against gas temp. change. Serial interface provided as the standard. Power supply: Both 100VAC and 12VDC adaptors provided. |
|